Thursday, November 26, 2026

Microsoft Dynamics 365 SCM: PROD Upgrade Automatically Cancelled Due to Sandbox Upgrade Failure

Recently, we have encountered an issue affecting some clients where the PROD environment upgrade was automatically moved to the Cancelled state.

According to Microsoft's standard auto-upgrade procedure, the designated sandbox environment is upgraded to the latest version one week before the PROD upgrade. If the sandbox upgrade fails, Microsoft automatically pauses or cancels the scheduled PROD upgrade.

To identify the reason for the failure, the upgrade logs in the sandbox environment should be reviewed.

In our case, the logs indicated the following error:

Invalid column name 'group_id'


After checking Microsoft's known issues, we identified this as a known issue related to the auto-update process. During the upgrade, Microsoft attempts to deploy the baseline package, which causes the failure.

Resolution

To resolve the issue, deploy the latest PQU package to the sandbox environment. This ensures that the correct package is used during the upgrade process.

The latest PQU package is also the package that should be deployed to PROD, rather than the baseline 10.0.49 package.